Analysis of Automatic Liquid Chromatography

**Liquid Chromatography Operating Procedures** Liquid chromatography is a widely used analytical technique for separating, identifying, and quantifying compounds in a mixture. Proper operation of the liquid chromatography system ensures accurate and reliable results. Below is a detailed guide to operating the system. **1. Power On Sequence** Before starting the instrument, ensure that all components are properly connected. Turn on the power in the following order: - Pump - Detector - Computer host - Monitor - Printer **2. Launching the Chromatography Workstation Software** Double-click the "Chromatography Workstation" icon on the desktop. Enter the password “SAGE” and click OK. Then, select the “Alltech-426” icon to begin the session. **3. Setting Chromatographic Conditions** - **Pump Settings**: Adjust the flow rate using the arrow keys. Press RUN/STOP to start the pump. - **Detector Settings**: After the detector passes its self-test, set the required wavelength. Use the ZERO button to reset the baseline before analysis. **4. Preparing the Mobile Phase** Mix the mobile phase according to the desired volume ratio. Ensure thorough mixing, then filter and sonicate for 20 minutes to remove any air bubbles. **5. System Preparation** - Insert the filter into the mobile phase reservoir. - Open the bypass valve on the pump and press the PURGE button. Use a syringe to draw and flush the mobile phase until no air bubbles remain in the tubing. - Press RUN/STOP to activate the pump. **6. Sample Injection and Analysis** - On the computer, click the blue “RUN/SINGLE” icon. Rename the data file (e.g., SAM01.001) and click OK. - Load the injection valve to the LOAD position. Inject the sample using a microliter syringe. Press the detector’s ZERO key, then move the injection valve to the INJECT position and press the spacebar on the keyboard. The system will begin analysis. **7. Data Collection and Reporting** - Once the chromatogram is complete, the system stops automatically. Click the “Analyze” icon to calculate peak areas. - Select “Reports” and choose “Area%” to view the results. To print, click the printer icon, select “Print Report P,” and choose “Custom C.” **8. Repeating the Process** Repeat the injection and analysis steps for each sample. Allow about 5 minutes between samples for system stability. **9. Shutting Down the System** Before turning off the system: - Flush the column with the mobile phase for 20–30 minutes. If the column will not be used for an extended period, rinse it with pure acetonitrile. - Turn off the pump, detector, monitor, and computer in reverse order. Always exit the software before powering down. **Notes:** - Never turn off the computer while the software is running. - The pump flow rate should not exceed 1.5 mL/min under normal conditions. - The pump will not start if the mobile phase is depleted. **Modifying Analysis Conditions** - **Adjusting Run Time**: Go to “Setup,” set the sampling frequency to 2, and define the run time (e.g., 10 or 20 minutes). Save the method after setting the channel status and trigger options. - **Integral Parameters**: Modify the Minimun Area, Width, and Threshold values in the Integral Parameter Table to refine peak detection. - **Report Format**: Customize the report by selecting fields like File Name, User Name, Date, and Peak Information. Set column widths and decimal places as needed. - **Accessing Previous Methods**: Use the Method and Data icons to load previous methods or data files. **Internal Standard Method** - Select the appropriate method and enter the standard. - After recording the spectrum, adjust the calibration settings and input the internal standard concentration. - Recalculate and verify the correction factor. Repeat for unknown samples and print the results. **External Standard Method** - Follow similar steps as the internal standard method, but use external standards for calibration. - Input the standard concentrations and verify the calibration curve. Calculate the standard deviation and proceed with sample analysis. **Company Information** Shanghai Qite Analytical Instrument Co., Ltd. Website: http://www.qite.com.cn Contact: Tel/Fax: +86-21-XXXXXXX For more information, visit: http://news.chinawj.com.cn This guide provides a comprehensive overview of liquid chromatography operations. Following these procedures ensures consistent and accurate results. Always refer to the manufacturer's instructions for specific details related to your equipment.

Chloride Free Sandwich Board Substrate

Chloride Free Sandwich Board Substrate

Shangdong Oushibao New Materials Co.,Ltd , https://www.oushibaomgo.com